74VHC594
RECOMMENDED OPERATING CONDITIONS
Symbol
VCC
VI
VO
Top
dt/dv
Parameter
Supply Voltage
Input Voltage
Output Voltage
Operating Temperature
Input Rise and Fall Time (note 1) (VCC = 3.3 ± 0.3V)
(VCC = 5.0 ± 0.5V)
1) VIN from 30% to 70% of VCC
Value
2 to 5.5
0 to 5.5
0 to VCC
-55 to 125
0 to 100
0 to 20
Unit
V
V
V
°C
ns/V
DC SPECIFICATIONS
Test Condition
Value
Symbol
Parameter
VCC
(V)
VIH High Level Input
Voltage
2.0
3.0 to
5.5
VIL Low Level Input
Voltage
2.0
3.0 to
5.5
VOH High Level Output 2.0
Voltage
3.0
4.5
3.0
4.5
VOL Low Level Output 2.0
Voltage
3.0
4.5
3.0
4.5
II
Input Leakage
0 to
Current
5.5
Ioff
Power Off Leakage
Current
0
ICC
Quiescent Supply
Current
5.5
TA = 25°C
-40 to 85°C -55 to 125°C Unit
Min. Typ. Max. Min. Max. Min. Max.
1.5
0.7VCC
1.5
1.5
0.7VCC
0.7VCC
V
0.5
0.3VCC
0.5
0.3VCC
0.5
0.3VCC V
IO=-50 µA
IO=-50 µA
IO=-50 µA
IO=-4 mA
IO=-8 mA
IO=50 µA
IO=50 µA
IO=50 µA
IO=4 mA
IO=8 mA
1.9 2.0
1.9
1.9
2.9 3.0
2.9
2.9
4.4 4.5
4.4
4.4
V
2.58
2.48
2.4
3.94
3.8
3.7
0.0 0.1
0.1
0.1
0.0 0.1
0.1
0.1
0.0 0.1
0.1
0.1 V
0.36
0.44
0.55
0.36
0.44
0.55
VI = 5.5V or GND
± 0.1
±1
± 1 µA
VI = 0 to 5V
± 0.1
±5
± 5 µA
VI = VCC or GND
4
40
40 µA
5/11