CXD3410GA
AC Characteristics
AC characteristics between the serial interface clocks
SSI2
SCK2
SEN2
SEN2
0.2VDD
0.2VDD
ts3
0.8VDD
0.8VDD
ts1
th1
0.8VDD
ts2
∗ The setting values are reflected to the operation 5 or 6 ADCLKI clocks after the serial data is loaded at the
rise of SEN2.
Symbol
tp1
ts1
th1
ts2
ts3
(Fc = 18MSPS, DVDD1, 2 = AVDD1, 2, 3, 4, 5 = 3.3V, Ta = 25°C)
Definition
Min. Typ. Max. Unit
SCK2 clock period
100
ns
SSI2 setup time, activated by the rise of SCK2
30
ns
SSI2 hold time, activated by the rise of SCK2
30
ns
SCK2 setup time, activated by the rise of SEN2
30
ns
SEN2 setup time, activated by the rise of SCK2
30
ns
– 16 –