X9313
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
+70°C
+85°C
+125°C
3866 PGM T03.1
Supply Voltage
X9313
X9313-3
Limits
5V ±10%
3V to 5.5V
3866 PGM T04.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC
VCC Active Current
ISB
Standby Supply Current
ILI
VIH
VIL
RW
VVH
VVL
CIN(5)
CS, INC, U/D Input
Leakage Current
CS, INC, U/D Input
HIGH Voltage
CS, INC, U/D Input
LOW Voltage
Wiper Resistence
VH Terminal Voltage
VL Terminal Voltage
CS, INC, U/D Input
Capacitance
Min.
Limits
Typ.(4)
1
200
Max.
3
500
±10
Units
mA
µA
µA
Test Conditions
CS = VIL, U/D = VIL or VIH and
INC = 0.4V/2.4V @ max. tCYC
CS = VCC – 0.3V, U/D and INC =
VSS or VCC – 0.3V
VIN = VSS to VCC
2
VCC + 1 V
–1
0.8
V
40
–5
–5
100
Ω Max. Wiper Current ±1mA
+5
V
+5
V
10
pF VCC = 5V, VIN = VSS,
TA = 25°C, f = 1MHz
3866 PGM T05.3
STANDARD PARTS
Part Number
Maximum Resistance
Wiper Increments
Minimum Resistance
X9313Z
X9313W
X9313U
X9313T
1KΩ
10KΩ
50KΩ
100KΩ
Notes: (4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
32.3Ω
323Ω
2381Ω
3226Ω
40Ω
40Ω
40Ω
40Ω
3866 PGM T08.1
5