DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FS9922-DMM4-DS-11 データシートの表示(PDF) - Unspecified

部品番号
コンポーネント説明
メーカー
FS9922-DMM4-DS-11 Datasheet PDF : 39 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
FS9922-DMM4
8.2 Electrical Parameters
Symbol
Parameter
Test Condition Min. Typical Max. Unit
VDD
IDD
Recommended
Power Voltage
Operation Current
Operation
In DCV Mode
2.4
3.6
V
1.5
3
mA
IPO Sleep Current
VIH
Digital High Voltage Level
In Auto Power-off Status
VDD-0.5
10
µA
V
VIL
AGND
VDDA
Digital Low Voltage Level
Analog Ground Voltage
Analog Power Supply
0.5
V
VDDA/2
-3%
VDDA/2
VDDA/2
+3%
V
3.4
3.9
4.4
V
VBAND Built in Bandgap Voltage
Voltage Relative to
AGND
1.1
1.25
1.4
V
Coefficient of curve of Bandgap
Voltage along with power
VDD=2.43.6V
2
mV/V
voltage
REFI
Recommended
Voltage
referenced Voltage Relative to
AGND
0.63
V
VBATT Low Voltage Detector
Use DC 3V
2.25
2.4
2.55
V
FLCD
VLCD
FBEEP
LCD Frequency
LCD PK-PK Driver Voltage
Buzzer Frequency
32
Hz
2.8
3
3.2
V
2.7
kHz
FRS232
IRSOUT
RS232 Baud Rate
RS232 Transmission
Voltage Level Current
“0”Input Reading
High
VOH=2V
DC ADP×1
Input=0V
2400
bps
2
mA
-1
0
1
digits
Linearity (Max. Deviation From
DC ADP×1
Best Straight Line Fit)
Full Scale±400mV
-1
0
1
Bit
AC Measurement Bandwidth
Error
AC ADP×1
Input 400mVrms
20Hz~1kHz
0.2
%
RCC Continuity Check Value
10
60
ADC Measurement O.L Display
Count
6040
counts
Auto range Up Count
6040
counts
Auto range Down Count
560
counts
VFREA
Frequency Count
(Hz/Duty Control)
Voltage VIL (relative to AGND)
-60
mV
VIH (relative to AGND)
60
mV
FMAXA
Max. Frequency Input (Hz/Duty
Control)
Vpp=±100mV
Square Wave Input
500
kHz
*1
Duty Cycle Measurement
Vpp=±100mV
Deviation (Hz/Duty Control)
Square Wave Input
1
µs
VFRED
FMAX
*1
Frequency Count Input Voltage VIL (relative to AGND)
(MEAS=10100)
VIH (relative to AGND)
(MEAS=10100) Input Frequency
Vpp=±600mV
of Frequency Count
Square Wave Input
(MEAS=10100)Duty
Cycle
Vpp=±600mV
Measurement Deviation
Square Wave Input
-600
5
mV
600
mV
MHz
100
ns
Accuracy of Capacitance 60.00 nF Mode
2%+10 digits
Measurement in Relative Value
Measurement Status (by
600.0nF Mode standard
adjustment)
600.0 nF Mode
6.000 µF Mode
60.00 µF Mode
0.5%+3
1%+2
1.5%+2
digits
digits
digits
*1 During Duty Cycle measurement, when a square wave is input, the difference comes mainly from the analyzable impulse
width difference of the competitor. If the input is a 100kHz square wave, which can be divided into 1000 counts, each count
is 10 ns. Therefore, the max. difference is 100ns/10 ns=10Counts, 50.0%±1.0% can be measured from 50.0% of output
signal. The signal larger than 99% or less than 1% might not be able to be measured.
Rev. 1.1
10/39

Share Link: 