MX26L6420
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . ..... -65oC to +150oC
Ambient Temperature
with Power Applied. . . . . . . . . . . . . .... -65oC to +125oC
Voltage with Respect to Ground
VCC (Note 1) . . . . . . . . . . . . . . . . . -0.5 V to +4.0 V
A9, OE, and
RESET (Note 2) . . . . . . . . . . . ....-0.5 V to +12.5 V
All other pins (Note 1) . . . . . . . -0.5 V to VCC +0.5 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes:
1. Minimum DC voltage on input or I/O pins is -0.5 V.
During voltage transitions, input or I/O pins may over-
shoot VSS to -2.0 V for periods of up to 20 ns. See
Figure 6. Maximum DC voltage on input or I/O pins is
VCC +0.5 V. During voltage transitions, input or I/O
pins may overshoot to VCC +2.0 V for periods up to
20 ns. See Figure 7.
2. Minimum DC input voltage on pins A9, OE, and
RESET is -0.5 V. During voltage transitions, A9, OE,
and RESET may overshoot VSS to -2.0 V for periods
of up to 20 ns. See Figure 6. Maximum DC input volt-
age on pin A9 is +12.5 V which may overshoot to 14.0
V for periods up to 20 ns.
3. No more than one output may be shorted to ground at
a time. Duration of the short circuit should not be
greater than one second.
Stresses above those listed under "Absolute Maximum
Rat-ings" may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device at these or any other conditions above those in-
dicated in the operational sections of this data sheet is
not implied. Exposure of the device to absolute maxi-
mum rating conditions for extended periods may affect
device reliability.
OPERATING RATINGS
Commercial (C) Devices
Ambient Temperature (TA ). . . . . . . . . . . . 0°C to +70°C
Industrial (I) Devices
Ambient Temperature (TA ). . . . . . . . . . -40°C to +85°C
VCC Supply Voltages
VCC for full voltage range. . . . . . . . . . . +2.7 V to 3.6 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.
P/N:PM0823
REV. 0.5, JAN. 29, 2002
15

Share Link: 