NJU6682
The example and the method of Partial Display are listed below.
UNIT 0
UNIT 1
:
UNIT 14
UNIT 15
:
UNIT 28
UNIT 29
:
the 1st Block
Available Display Area
the 2nd Block
(1)Set the Start Unit of the 1st Block “0”.
(R/W)
A0 RD WR D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0100011000000000000
(2)Set the Display Unit Number of the 1st Block “2”.
(R/W)
A0 RD WR D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0100011000100000010
(3)Set the Start Unit of the 2nd Block “14”.
(R/W)
A0 RD WR D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0100011001000001110
(4)Set the Display Unit Number of the 2nd Block “16”.
(R/W)
A0 RD WR D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0100011001100010000
Then, the Duty will be changed to 1/128 automatically.
(4)Execute the Partial Display
(R/W)
A0 RD WR D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0100011010000000000