Electrical Characteristics (Ta = 25°C)
Characteristics
Symbol
Test Condition
Gate leakage current
Drain cut−off current
Drain−source breakdown voltage
Gate threshold voltage
Drain−source ON resistance
Forward transfer admittance
Input capacitance
Reverse transfer capacitance
Output capacitance
IGSS
IDSS
V (BR) DSS
Vth
RDS (ON)
|Yfs|
Ciss
Crss
Coss
VGS = ±16 V, VDS = 0 V
VDS = 100 V, VGS = 0 V
ID = 10 mA, VGS = 0 V
VDS = 10 V, ID = 1 mA
VGS = 4 V, ID = 0.5 A
VGS = 10 V, ID = 0.5 A
VDS = 10 V, ID = 0.5 A
VDS = 10 V, VGS = 0 V, f = 1 MHz
Rise time
tr
2SK2962
Min Typ. Max Unit
—
—
±10
μA
—
—
100
μA
100
—
—
V
0.8
—
2.0
V
— 0.65 0.95
Ω
—
0.5 0.7
0.6 1.2
—
S
— 140 —
—
20
—
pF
—
45
—
—
8
—
Turn−on time
ton
Switching time
Fall time
tf
—
13
—
100
ns
—
45
—
Turn−off time
Total gate charge (gate−source
plus gate−drain)
Gate−source charge
Gate−drain (“miller”) Charge
toff
Qg
Qgs
VDD ≈ 80 V, VGS = 10 V, ID = 1 A
Qgd
— 175 —
—
6.3
—
—
4.3
—
nC
—
2
—
Source–Drain Ratings and Characteristics (Ta = 25°C)
Characteristics
Continuous drain reverse current
(Note 1)
Pulse drain reverse current
(Note 1)
Forward voltage (diode)
Reverse recovery time
Reverse recovery charge
Symbol
Test Condition
IDR
—
IDRP
VDSF
trr
Qrr
—
IDR = 1 A, VGS = 0 V
IDR = 1 A, VGS = 0 V, dIDR / dt = 50 A / μs
Min Typ. Max Unit
—
—
1
A
—
—
3
A
—
—
−1.5
V
—
80
—
ns
— 140 —
nC
Marking
K2962
Part No.
(or abbreviation code)
Lot No.
Note 4
Note 4: A line under a Lot No. identifies the indication of product
Labels.
Not underlined: [[Pb]]/INCLUDES > MCV
Underlined: [[G]]/RoHS COMPATIBLE or [[G]]/RoHS [[Pb]]
Please contact your TOSHIBA sales representative for details as to
environmental matters such as the RoHS compatibility of Product.
The RoHS is the Directive 2002/95/EC of the European Parliament
and of the Council of 27 January 2003 on the restriction of the use of
certain hazardous substances in electrical and electronic equipment.
2