First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
250 μmho
115 μmho
voltage building time at light load. FAN7930 has
“overshoot-less” control at startup. During startup, the
feedback loop is controlled by an internal proportional
gain controller and when the output voltage reaches the
rated value, it switches to an external compensator after
a transition time of 30ms. In short, an internal
proportional gain controller eliminates overshoot at
startup and an external conventional compensator takes
over successfully afterward.
Figure 33. Gain Characteristic
6. Soft-Start: When VCC touches VSTART, internal
reference voltage is increased like a stair step for 5ms.
As a result, VCOMP is also raised gradually and MOSFET
turn-on time increases smoothly. This reduces voltage
and current stress on the power switch during startup.
Figure 35. Overshoot-less Startup Control
Figure 34. Soft-Start Sequence
7. “Overshoot-less” Startup: Feedback control speed
of PFC is quite slow. Due to the slow response, there is
a gap between output voltage and feedback control.
That is why over-voltage protection (OVP) is critical at
the PFC controller and voltage dip caused by fast load
changes from light to heavy is diminished by a bulk
capacitor. OVP is easily triggered at startup phase.
Operation on and off by OVP at startup may cause
audible noise and can increase voltage stress at startup,
which is normally higher than in normal operation. This
operation is better when soft-start time is very long.
However, too long startup time enlarges the output
8. THD Optimization: Total harmonic distortion (THD)
is the factor that dictates how closely input current
shape matches sinusoidal form. The turn-on time of the
PFC controller is almost constant over one AC line
period due to the extremely low feedback control
response. The turn-off time is decided by the current
decrease slope of the boost inductor made by the input
voltage and output voltage. Once inductor current
becomes zero, resonance between COSS and the boost
inductor makes oscillating waveforms at the drain pin
and auxiliary winding. By checking the auxiliary winding
voltage through the ZCD pin, the controller can check
the zero current of boost inductor. At the same time, a
minor delay time is inserted to determine the valley
position of drain voltage. The input and output voltage
difference is at its maximum at the zero cross point of
AC input voltage. The current decrease slope is steep
near the zero cross region and more negative inductor
current flows during a drain voltage valley detection
time. Such a negative inductor current cancels down the
positive current flows and input current becomes zero,
called “zero-cross distortion” in PFC.