MAX16050/MAX16051
Voltage Monitors/Sequencer Circuits with
Reverse-Sequencing Capability
PART DOES NOT RESPOND TO EN FALLING
...UNTIL EN_HOLD GOES HIGH
EN
EN_HOLD
CONNECTED TO REM OF THE SECOND IC
V1
V2
V3
V4
Figure 5. Power-Down Characteristics when REM of the Second IC is Connected to EN_HOLD of the First IC.
See the Typical Application Circuit (Figure 1).
www.maximintegrated.com
Maxim Integrated │ 13