AD9891/AD9895
Register
Length
HDLEN
12b
VxSTART
12b
VxSPTRFIRST 4b
VxINVFIRST 1b
x is the V-output from 14.
Table VIII. Individual Vertical Region Parameters
Range
04095 Pixels
04095 Pixel Location
Sequence 011
High/Low
Description
HD Line Length for Lines in Each Region 04
Sequence Start Position for Each Vx Output in Each Region 04
Sequence Pointer for Vx Output during Each Region 04
(Can Be Used with SPTRSECOND for Alternation, See Text)
When High, the Polarity of Sequence VxSPTRFIRST Is Inverted
Complete Field: Combining the Regions
The individual regions are combined into a complete field readout
by using region change positions (RCP) and region pointers
(REGPTR). Figure 22 shows how each field is divided into
multiple regions. This allows the user to change the vertical
timing during various stages of the image readout. The boundaries
of each region are defined by the sequence change positions
(RCP). Each RCP is a 12-bit value representing the line number
bounding the region. A total of seven RCPs allow up to eight
different region areas in the field to be defined. The first RCP is
always hard-coded to zero, and the remaining seven are register
programmable. Note that there are only five possible individual
regions that can be defined, but the eight region areas allow the
same region to be used in more than one place during the field.
Within each region area, the region pointers specify which of the
five individual regions will be used. There are eight region
pointers, one for each region area. Table IX summarizes the
registers for the region change positions and region pointers.
REGION CHANGE POSTION #0
(V-COUNTER = 0)
REGION CHANGE POSTION #1
REGION CHANGE POSTION #2
REGION CHANGE POSTION #3
REGION CHANGE POSTION #4
REGION CHANGE POSTION #5
SINGLE FIELD (1 VD INTERVAL)
USE THE REGION SPECIFIED BY REGION POINTER 0
USE THE REGION SPECIFIED BY REGION POINTER 1
USE THE REGION SPECIFIED BY REGION POINTER 2
USE THE REGION SPECIFIED BY REGION POINTER 3
USE THE REGION SPECIFIED BY REGION POINTER 4
USE THE REGION SPECIFIED BY REGION POINTER 5
REGION CHANGE POSTION #6
REGION CHANGE POSTION #7
USE THE REGION SPECIFIED BY REGION POINTER 6
USE THE REGION SPECIFIED BY REGION POINTER 7
UP TO EIGHT V-CLOCK REGION AREAS MAY BE DEFINED WITHIN ONE FIELD BY
USING THE REGION CHANGE POSITION AND THE REGION POINTERS.
Figure 22. Complete Field Using Multiple Region Areas
Register
VTPRCP
VTPREGPTR
Length
12b
3b
Table IX. Complete Vertical Field Registers
Range
04095 Line Location
Region 04
Description
Region Change Position for each Region Area in Field
Region Pointer for each Region Area of Field