First Prev 11 12 13 14 15 16 17 18
ADM1032
1
91
9
SCLK
SDATA
A6
START BY
MASTER
A5 A4 A3 A2 A1 A0
FRAME 1
SERIAL BUS ADDRESS BYTE
R/W
D7
ACK. BY
ADM1032
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY
ADM1032
1
9
SCLK (CONTINUED)
SDATA (CONTINUED)
D7 D6 D5 D4 D3 D2 D1 D0
FRAME 3
DATA BYTE
ACK. BY STOP BY
ADM1032 MASTER
Figure 13. Writing a Register Address to the Address Pointer Register,
then Writing Data to the Selected Register
1
9
1
9
SCLK
A6
SDATA
START BY
MASTER
A5 A4 A3 A2 A1 A0 R/W
D7
FRAME 1
SERIAL BUS ADDRESS BYTE
ACK. BY
ADM1032
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY STOP BY
ADM1032 MASTER
Figure 14. Writing to the Address Pointer Register Only
19
SCLK
1
9
SDATA
A6
START BY
MASTER
A5 A4 A3 A2 A1 A0 R/W
D7 D6
FRAME 1
SERIAL BUS ADDRESS BYTE
ACK. BY
ADM1032
D5 D4 D3 D2 D1
FRAME 2
DATA BYTE FROM ADM1032
Figure 15. Reading Data from a Previously Selected Register
D0
ACK. BY STOP BY
ADM1032 MASTER
ALERT Output
The ALERT output goes low whenever an outoflimit
measurement is detected, or if the remote temperature sensor
is opencircuit. It is an open drain and requires a pullup to
VDD. Several ALERT outputs can be wireOR’ed together
so that the common line goes low if one or more of the
ALERT outputs goes low.
The ALERT output can be used as an interrupt signal to a
processor, or it can be used as an SMBALERT. Slave devices
on the SMBus can not normally signal to the master that they
want to talk, but the SMBALERT function allows them to do
so.
One or more ALERT outputs can be connected to a
common SMBALERT line connected to the master. When
the SMBALERT line is pulled low by one of the devices, the
following procedure occurs (see Figure 16).
MASTER
RECEIVES
SMBALERT
START
ALERT RESPONSE
ADDRESS
MASTER SENDS
ARA AND READ
COMMAND
RD ACK
DEVICE
ADDRESS
NO
ACK
STOP
DEVICE SENDS
ITS ADDRESS
Figure 16. Use of SMBALERT
1. SMBALERT is pulled low.
2. Master initiates a read operation and sends the
alert response address (ARA = 0001 100). This is
a general call address that must not be used as a
specific device address.
3. The device whose ALERT output is low responds
to the alert response address and the master reads
its device address. Since the device address is
http://onsemi.com
12