DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CXA3272R データシートの表示(PDF) - Sony Semiconductor

部品番号
コンポーネント説明
メーカー
CXA3272R Datasheet PDF : 46 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CXA3272R
Item
Symbol
Serial data
settings
Measurement conditions
Min.
RGB signal output block
RGB frequency
response
FRGBH
LPF 0
TONE 1
FRGBL
LPF 1
TONE 1
SW59, SW60 and SW61 = B
Assume the output amplitude at LPF high 5.5
TP43 when SIG1 (0dB, 100kHz)
is input to (A) as 0dB.
Vary the frequency of the input
signal to obtain the frequency
with an output amplitude of 3dB. LPF Low 4.0
S/H OFF, RGB input
RGB signal DC
output voltage
VOUT
SW59, SW60 and SW61 = B
Input SIG4 (VL = 0mV) to (A) and adjust
serial bus register BRIGHT so that the
output at TP43 is 9Vp-p (black-black).
5.8
Measure the DC voltage at TP40, TP43 and
TP45.
RGB signal DC
voltage difference
dVOUT
Obtain the maximum difference between
each of the DC voltage measurement
values of TP40, TP43 and TP45 in the
preceding item VOUT.
RGB maximum
output range
SW59, SW60 and SW61 = B
OUTMAX
BRT 0
U-BRT 0
Input SIG4 (VL = 0mV) to (A) and measure
the output amplitude (black-black) at TP40,
9.8
TP43 and TP45.
SIG.C variable
range
VORNG
SW48 = ON
Adjust V48 to 5.2V or 6.5V in the VOUT
measurement conditions and confirm that
5.2
dVOUT is satisfied and that |V48 VOUT|
0.15V.
SW59, SW60 and SW61 = B
UBRTMX
U-BRT 255
CONT 255
Input SIG2 to (A) and measure the amount
of change in the black level output at TP40,
TP43 and TP45 when serial bus register
2.0
Amount of change
U-BRIGHT is changed from 128 to 255.
in U-BRIGHT
SW59, SW60 and SW61 = B
UBRTMN
U-BRT 0
CONT 255
Input SIG2 to (A) and measure the amount
of change in the white level output at TP40,
TP43 and TP45 when serial bus register
U-BRIGHT is changed from 128 to 0.
SW59, SW60 and SW61 = B
BRTMX
BRT 255
CONT 255
Input SIG2 to (A) and measure the amount
of change in the black level output at TP40,
TP43 and TP45 when serial bus register
2.0
Amount of change
BRIGHT is changed from 128 to 255.
in BRIGHT
SW59, SW60 and SW61 = B
BRTMN
BRT 0
CONT 255
Input SIG2 to (A) and measure the amount
of change in the white level output at TP40,
TP43 and TP45 when serial bus register
BRIGHT is changed from 128 to 0.
Typ. Max. Unit
MHz
MHz
6.0 6.2 V
0 120 mV
V
6.5 V
3.0
V
3.0 2.0 V
2.5
V
2.5 2.0 V
15

Share Link: 