M29DW323DT, M29DW323DB
Enter Extended Block Command
The M29DW323D has an extra 64KByte block
(Extended Block) that can only be accessed using
the Enter Extended Block command. Three Bus
write cycles are required to issue the Extended
Block command. Once the command has been is-
sued the device enters Extended Block mode
where all Bus Read or Program operations to the
Boot Block addresses access the Extended Block.
The Extended Block (with the same address as
the boot block) cannot be erased, and can be
treated as one-time programmable (OTP) memo-
ry. In Extended Block mode the Boot Blocks are
not accessible. In Extended Block mode dual op-
erations are possible, with the Extended Block
mapped in Bank A. When in Extended Block
mode, Erase Commands in Bank A are not al-
lowed.
To exit from the Extended Block mode the Exit Ex-
tended Block command must be issued.
The Extended Block can be protected, however
once protected the protection cannot be undone.
Exit Extended Block Command
The Exit Extended Block command is used to exit
from the Extended Block mode and return the de-
vice to Read mode. Four Bus Write operations are
required to issue the command.
Block Protect and Chip Unprotect Commands
Groups of blocks can be protected against acci-
dental Program or Erase. The Protection Groups
are shown in APPENDIX A., Tables 23 and 24,
Block Addresses. The whole chip can be unpro-
tected to allow the data inside the blocks to be
changed.
Block Protect and Chip Unprotect operations are
described in APPENDIX D.
Table 5. Commands, 16-bit mode, BYTE = VIH
Bus Write Operations
Command
1st
2nd
3rd
4th
5th
6th
Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data
Read/Reset
1 X F0
3 555 AA 2AA 55 X F0
Auto Select
3 555
AA
2AA
55
(BKA)
555
90
Program
4 555 AA 2AA 55 555 A0 PA PD
Double Word Program 3 555 50 PA0 PD0 PA1 PD1
Unlock Bypass
3 555 AA 2AA 55 555 20
Unlock Bypass
Program
2 X A0 PA PD
Unlock Bypass Reset 2 X 90 X 00
Chip Erase
6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10
Block Erase
6+ 555 AA 2AA 55 555 80 555 AA 2AA 55 BA 30
Erase Suspend
1 BKA B0
Erase Resume
1 BKA 30
Read CFI Query
1 55 98
Enter Extended Block 3 555 AA 2AA 55 555 88
Exit Extended Block
4 555 AA 2AA 55 555 90 X 00
Note: X Don’t Care, PA Program Address, PD Program Data, BA Any address in the Block, BKA Bank Address. All values in the table are in
hexadecimal.
The Command Interface only uses A–1, A0-A10 and DQ0-DQ7 to verify the commands; A11-A20, DQ8-DQ14 and DQ15 are Don’t
Care. DQ15A–1 is A–1 when BYTE is VIL or DQ15 when BYTE is VIH.