Adding DTLx485 Active X Control to Your Project's
Toolbox
After installing the WinBurn™ DTLx485, you can add the
control to your Visual Basic-based application as follows:
On the menu tab, select Project, and then click on
Components, which will display a Components Dialog
Box (see Figure _ _). Alternatively, right-clicking on the
Toolbox also brings up the Component Dialog Box. To
add the DTLx485 ActiveX control to your application
project, click on the Browse button, and locate the
DTLx485.ocx file (WinBurn™ default directory of
C:\Program Files\DATEL\DTLx\DTLx485. Click on the
DTLx485.ocx file to add it to the Components list. Now,
either double-click on the DTLx485, or select the check
box to the left of the DTLx485 name to add it to the
Toolbox. Click OK to close the Components dialog box.
DTLx485ctl Class/Members
Under Visual Basic, the WinBurn™ DTLx485 ActiveX
Control has the "Class" DTLx485ctl, with the following
"Members" to point out:
CheckFaultStatus
Function: Returns the status
of the DTLXA Series Fault Line
0 = No Fault
1 = Fault
2 = Time Out
3 = Port Not Open
ClosePort
Function: Closes the Serial
Communication Port
8 = Run time error
Col
Property: Sets the DTLXA
Series load position (Column =
X)
0 -15
ELType (DtlType?)
Property: Sets the DTLXA
Series Model Used (Current/
Voltage)
2 =DTL2A/DTL2A-LC
3 = DTL3A
4 = DTL4A
LastReadVoltage
Property: Reports the last A/D
reading
-1 = Error
LoadStoredCurrent
SubRoutine: Updates load to
value set for load
OpenPort
Function: Opens the Serial
Communication Port
PortNumber
Property: Returns/sets the
Communication Port
ReadVoltage
Function: Performs A/D
conversion to read voltage
(presumably at load)
RequestAmps
Property: Prepares the load
for the current value to be
loaded with the
StoreLoadCurrent and
SetLoadCurrent commands
12
ResetAllLoads
ResetLoads
individual
load to zero current
Row
SetAllLoadCurrents
SetLoadCurrent
StoreLoadCurrent
SubRoutine: Resets all loads
to zero current
SubRoutine: Resets
Property: Sets the DTLXA
Series load position (Row =
Y)
0 - 15
Function: Sets all DTLXA
Series Load Input Latches to
the same load current value.
This command requires all
loads to be of the same type
voltage/current (i.e., all 20A/
50V models)
Function: Sets DTLXA Series
Load with load current value
to be set with next
"StoreLoadCurrent", after
RequestAmps sets value
Function: Updates load to
value set for load
In general: Default properties are:
Com Port = 5 (typical for 485 board...reset to 1 or 2 if
using PC's com Port.
Load = 2 for a DTL2A, change if DTL3A or DTL4A
Row/Column set to 1st unit (0,0), change for multiple unit
systems.
To set a particular load's current, you'll first set
properties if the Default settings don't apply. Then you'll
do a RequestAmps, to set the desired current value.
Then, a StoreLoad Current will enter this into the 1st
latch. Finally, a SetLoadCurrent (or SetAll Load
Currents) command, will update the loads with a new
value.
WinBurn™ DTLx485, Port Control
Developing an application that controls "instruments", whether
they be test systems or burn-in racks, requires a user to first
check the communication between the PC and the
"instruments". The DTL-IFB can be connected to a standard
PC RS232 COM port with an appropriate RS232/RS485
adapter (see Figure 4). Alternatively, a plug-in RS485 board
can be plugged into the PC. COM1 and COM2 ports are
typically brought out on the rear of a PC, and plug-in cards
typically use COM3 or COM4.