DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

T-51440GL070HU-FW-AC データシートの表示(PDF) - Optrex Corporation

部品番号
コンポーネント説明
メーカー
T-51440GL070HU-FW-AC
Optrex
Optrex Corporation Optrex
T-51440GL070HU-FW-AC Datasheet PDF : 26 Pages
First Prev 21 22 23 24 25 26
8.Reliability Test
8.1.Mechanical and Environmental Test
Item
Condition
High temp operation Ta=65±2? , 45%RH Below
Test hour Remark
192 hrs Note1
High temp & high
humidity operation
Ta=65±2? , 90±2%RH, No Condensation
192 hrs
Low temp operation Ta=-30±3?
High temp storage Ta=85±2? , 45%RH below
192 hrs
192 hrs
Low temp storage Ta=-40±3?
192 hrs
Light resistance
Sunshine carbon arc Ta=63±2?
360 hrs
Drastic temp change -30? (60min)? 25? (15min)? 80? (60min), No electric path 20 cycle
Condensation
-30? (30min non-operating), 25? /95%RH(10min
operating)
Dried after specified cycle and confirm operation
1cycle= 48hrs non-operational
10cycle
Humidity cycle
65?
25?
2.5 2.5
8 hrs
2.5 3 2.5 2.5 3 2.5
2.5 3 2.5 2.5 3 2.5
0?
3
90~ 95%RH
5cycle
Note1
Note1
Note1
Note1
Note2
Static resistance
C=200pF, R=0O , V=±150V
3 discharge on electric and other terminal, non-operational
-
Electric discharge
Vibration
Shock
C=150pF, R=150O , V=±15kV
Discharge ±chrages 5 times each on panel and earth, non-
operational
5~ 10Hz, width 25mm
10~ 30Hz, 3.7×9.8m/s2
30~ 50Hz, 1.6×9.8m/s2
50~ 80Hz, 0.7×9.8m/s2
80~ 100Hz, 0.3×9.8m/s2
X,Y,Z all dir
8min×2sweep
non-operational
980m/s2, t=6ms, X,Y,Z all dir2,semi-sine-wave, non-
operational
-
All dir
96 hrs
-
Apply 500g of weight perpendicular to end of terminal
Terminal durability Onon-operational
-
External durability
Pressure resistance
Apply pressure on the center of the screen by push/pull gauge.
head diameter isf 12mm? pressured apply 5×9.8N(=5kgf)
once, non-opreatioal
5×104 Pa(=0.5Pressure)? non-operational
-
2 hrs
Note 1: High temperature operation, high temperature & high humidity operation, low temperature operation,
high temperature storage and low temperature storage will test it’s ability for 1000 hours to confirm.
The deteriortion of plarizer is disregarded.
Note 2: Drastic tempertaure change test will continue the inspection under same condition consecutiely to
confirm it’s ability. Test will be done mounted in your request kit.
T-51440GL070HU-FW-AC
OPTREX CORPORATION
OPTREX
Page 22/27

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]