KA5M0765RQC
Typical Performance Characteristics (Continued)
1.2
1.1
1.0
0.9
0.8
-100
※ Note :
1. VGS = 0 V
2. ID =250μ A
-50
0
50
100
150
200
TJ, Junction Temperature [oC]
Figure 7. Breakdown Voltage vs. Temperature
3.0
2.5
2.0
1.5
1.0
0.5
0.0
-100
※ Note :
1. VGS = 10 V
2. ID = 6.0 A
-50
0
50
100
150
200
TJ, Junction Temperature [oC]
Figure 8. On-Resistance vs. Temperature
102
Operation in This Area
is Limited by R DS(on)
101
100
10-1
100
100 µs
1 ms
10 ms
DC
※ Notes :
1. TC = 25 oC
2. T = 150 oC
J
3. Single Pulse
101
102
103
VDS, Drain-Source Voltage [V]
Figure 9. Max. Safe Operating Area
8
6
4
2
0
25
50
75
100
125
150
TC, Case Temperature [℃]
Figure 10. Max. Drain Current vs. Case Temperature
100
D=0.5
0.2
10-1 0.1
0.05
0.02
0.01
10-2
10-5
single pulse
※ Notes :
1. Zθ JC(t) = 0.9 ℃/W Max.
2. Duty Factor, D=t1/t2
3. TJM - TC = PDM * Zθ JC(t)
10-4
10-3
10-2
10-1
100
101
t1, Square Wave Pulse Duration [sec]
Figure 11. Thermal Response
6