LV8044LP,LV8044LQ
Constant-Current Control
Reference Voltage Setting (D0 = 1, D1 = 0, D2 = 1, D3 = 0 (channel 5) or D3 = 1 (channel 6))
D4
D5
D6
D7
Current setting reference voltage
0
0
0
0
0.300V
1
0
0
0
0.200V
0
1
0
0
0.190V
1
1
0
0
0.180V
0
0
1
0
0.170V
1
0
1
0
0.165V
0
1
1
0
0.160V
1
1
1
0
0.155V
0
0
0
1
0.150V
1
0
0
1
0.145V
0
1
0
1
0.140V
1
1
0
1
0.135V
0
0
1
1
0.130V
1
0
1
1
0.120V
0
1
1
1
0.110V
1
1
1
1
0.100V
The constant-current setting for channels 5 and 6 can be set individually for each channel.
(When D3 is 0, channel 5 is set, and when D3 is 1, channel 6 is set.)
The constant-current output value is set by the constant-current reference voltage set with the serial data and the value
of the resistor (referred to as "RF" here) connected to the RF5 or RF6 pin.
The formula below is used to calculated the constant-current output value.
<Constant-current output level> = <current setting reference voltage>/<RF resistor>