M29F800DT, M29F800DB
DC AND AC PARAMETERS
This section summarizes the operating measure-
ment conditions, and the DC and AC characteris-
tics of the device. The parameters in the DC and
AC characteristics Tables that follow, are derived
from tests performed under the Measurement
Conditions summarized in Table 9, Operating and
AC Measurement Conditions. Designers should
check that the operating conditions in their circuit
match the operating conditions when relying on
the quoted parameters.
Table 9. Operating and AC Measurement Conditions
M29F800D
Parameter
55
70/ 90
Unit
Min
Max
Min
Max
VCC Supply Voltage
4.5
5.5
4.5
5.5
V
Ambient Operating Temperature (range 1)
0
70
0
70
°C
Ambient Operating Temperature (range 3)
–40
125
–40
125
°C
Ambient Operating Temperature (range 6)
–40
85
–40
85
°C
Load Capacitance (CL)
30
100
pF
Input Rise and Fall Times
10
10
ns
Input Pulse Voltages
0 to 3
0.45 to 2.4
V
Input and Output Timing Ref. Voltages
1.5
0.8 and 2.0
V
Figure 9. AC Measurement I/O Waveform
High Speed (55ns)
3V
0V
Standard (70, 90ns)
2.4V
0.45V
1.5V
2.0V
0.8V
AI05276
Figure 10. AC Measurement Load Circuit
VCC
1.3V
1N914
DEVICE
UNDER
TEST
0.1µF
3.3kΩ
OUT
CL
CL includes JIG capacitance
AI05277
Table 10. Device Capacitance
Symbol
Parameter
CIN
Input Capacitance
COUT
Output Capacitance
Note: Sampled only, not 100% tested.
Test Condition
VIN = 0V
VOUT = 0V
Min
Max
Unit
6
pF
12
pF
19/39