M50LPW002
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 16. Operating Conditions
Symbol
Parameter
VCC
Supply Voltage
Ambient Operating Temperature (range 1)
TA
Ambient Operating Temperature (range 5)
Min.
Max.
Unit
3.0
3.6
V
0
70
°C
–20
85
°C
Figure 7. AC Measurement I/O Waveform (LPC Interface)
0.6 VCC
0.4 VCC
0.2 VCC
Input and Output AC Testing Waveform
IO < ILO
IO > ILO
IO < ILO
Output AC Tri-state Testing Waveform
AI03404
Table 17. AC Measurement Conditions (LPC Interface)
Symbol
Parameter
CL
Load Capacitance
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Reference Voltages
Min.
Max.
10
1.4
0.2VCC to 0.6VCC
0.4VCC
Unit
pF
ns
V
V
21/39