GaAs SP4T 2.5 V High Power Switch
DC - 3.0 GHz
MASW-008566
V1
Electrical Specifications: TA = 25°C, Z0 = 50 Ω 3
Parameter
Test Conditions
Units Min. Typ. Max.
Insertion Loss 4
Isolation
DC – 1 GHz
1 – 2 GHz
2 - 3 GHz
DC – 1 GHz
1 – 2 GHz
2 - 3 GHz
dB
0.65
0.85
dB
0.80
1.00
dB
1.00
dB
27
29.0
dB
21
23.0
dB
18.5
Return Loss
DC – 3 GHz
dB
20
IP3
IP2
P.1dB
2nd Harmonic
3rd Harmonic
Trise, Tfall
Ton, Toff
Transients
Two Tone +26 dBm, 5 MHz Spacing, > 50 MHz
VC = 0 V / 2.5 V
dBm
57
Two Tone +26 dBm, 5 MHz Spacing, > 50 MHz
VC = 0 V / 2.5 V
dBm
81
VC = 0 V / 2.5 V
dBm
38
1 GHz, PIN = +34 dBm, VC = 0 V / 2.5 V
dBc
-80
-71
1 GHz, PIN = +34 dBm, VC = 0 V / 2.5 V
dBc
-68
-65
10% RF to 90% RF, 90% to 10% RF, VC = 0 V / 2.5 V
µS
0.2
50% control to 90% RF, 50% control to 10% RF, VC = 0 V / 2.5 V µS
0.2
mV
35
Control Current
VC = 0 V / 2.5 V, 34 dBm
µA
10
50
3. External DC blocking capacitors are required on all RF ports.
4. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 - 500 MHz, 39 pF for 0.5 - 3 GHz.
Absolute Maximum Ratings 5,6
Parameter
Absolute Maximum
Input Power
(0.5 - 3.0 GHz, 2.5 V Control)
+38 dBm
Voltage
± 8.5 volts
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. M/A-COM does not recommend sustained operation near
these survivability limits.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive to
electrostatic discharge (ESD) and can be damaged by
static electricity. Proper ESD control techniques should
be used when handling these devices.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
Truth Table 7,8
V1 V2 V3 V4
ANT- ANT- ANT- ANT-
RF1 RF2 RF3 RF4
1 000
On
Off
Off
Off
0
1
00
Off
On
Off
Off
0 010
Off
Off
On
Off
0 001
Off
Off
Off
On
7. Differential voltage, V (state 1) -V (state 2), must be 2.5 V
minimum.
8. 0 = -5 V to +2.5 V, 1 = -2.5 V to +5 V
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.