DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MB15C03 データシートの表示(PDF) - Fujitsu

部品番号
コンポーネント説明
メーカー
MB15C03 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MB15C03
s PIN DESCRIPTIONS
Pin no.
1
2
3
Pin
name
VDD
Clock
Data
4
LE
5
fin
6
PS
7
LD
8
DO
9
VP
10
fr
11
fp
12
FC
13
TEST
14
OSCOUT
15
OSCIN
16
VSS
I/O System
Descriptions
1 V Power supply voltage
I
1V
Clock input for the shift register.
Data is shifted into the shift register on the rising edge of the clock.
I
1 V Serial data input using binary code.
Load enable signal input
I
1 V When LE is high, the data in the shift register is transferred to a latch,
according to the control bit in the serial data.
Prescaler input.
I
1 V A bias circuit and amplifier are at input port. Connection with an external
VCO should be done by AC coupling.
Power saving mode control. This pin must be set at “L” at Power-ON.
I
1 V PS = “H” ; Normal mode
PS = “L” ; Power saving mode
Lock detector signal output.
O
1 V When a PLL is locking, LD outputs “H”.
When a PLL is not locking, LD outputs “L”.
Charge pump output.
Phase of the charge pump can be reversed by FC input. The DO output
may be inverted by FC input. The relationships between the programm-
O
3V
able reference divider output(fr) and the programmable divider output(fp)
are shown below;
fr > fp : “H” level (FC= “L”), “L” level (FC= “H”)
fr = fp : High impedance
fr < fp : “L” level (FC= “L”), “H” level (FC= “H”)
3 V Power supply for the charge pump.
O
1 V Programmable reference counter output (fr) monitoring pin.
O
1 V Programmable counter output (fp) monitoring pin.
I
1 V Phase comparator input select pin.
Test mode select pin. (Pull down resistor)
I
1 V Setting this pin to “H”, test mode becomes available. Please set this pin
to ground or open usually.
O
1V
Oscillator output.
Connection for an external crystal.
Programmable reference divider input.
I
1V
Oscillator input.
Clock can be input to OSCIN from outside. In the case, please leave
OSCOUT pin open and make connection with OSCIN as AC coupling.
— Ground.
3