MB89143A/144A
s ELECTRICAL CHARACTERISTICS
1. Absolute Maximum Ratings
Parameter
Value
Symbol
Unit
Min.
Max.
(AVSS = VSS = 0.0 V)
Remarks
Power supply voltage
VCC
AVR
VSS – 0.3
VSS + 7.0
V
AVR ≤ VCC +0.3*1
VI1
VSS – 0.3
VCC + 0.3
V
P00 to P07, P10 to P17, P30,
P32 to P37, P70, P71
Input voltage
VI2
VSS – 0.3
7
V P31
VI3
VCC – 40
VCC + 0.3
V
P40 to P47, P50 to P57,
P60 to P67, BZ*2
Output voltage
VO1
VSS – 0.3
VCC + 0.3
V
P00 to P07, P10 to P17,
P20 to P23, P30 to P37
VO2
—
VCC + 0.3
V
P40 to P47, P50 to P57,
P60 to P67, BZ*2
“H” level total maximum
output current
ΣIOH
—
–100
mA
“H” level total average
output current
ΣIOHAV
—
–75
mA
Averge value (operating
current × operation rate)
“H” level maximum output
current
IOH
—
–12
P00 to P07, P30, P32 to P37,
P10 to P17, P20 to P23
mA
“H” level average output
current
IOHAV
—
–6
Average value (operating
current × operation rate)
“H” level maximum output
current
IOH
—
–20
P40 to P47, P50 to P57,
P60 to P67, BZ
mA
“H” level average output
current
IOHAV
—
–10
Average value (operating
current × operation rate)
“L” level total maximum
output current
ΣIOL
—
50
mA
“L” level total average
output current
ΣIOLAV
—
30
mA
Average value (operating
current × operation rate)
“L” level maximum output
current
IOL
“L” level average output
current
IOLAV
—
—
12
mA
P00 to P07, P10 to P17,
P20 to P23, P30 to P37
6
Power consumption
PD
—
470
mW SDIP64 : DIP-64P-M01
Operating temperature
TA
–40
+85
°C
Storage temperature
Tstg
–55
+150
°C
*1: Take care so that AVR does not exceed VCC + 0.3 V and VCC, such as when power is turned on.
*2: VI and VO must not exceed VCC + 0.3 V.
Precautions: Permanent device damage may occur if the above “Absolute Maximum Ratings” are exceeded. Func-
tional operation should be restricted to the conditions as detailed in the operational sections of this
data sheet. Exposure to absolute maximum rating conditions for extended periods may affect device
reliability.
19