DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ML9207 データシートの表示(PDF) - Oki Electric Industry

部品番号
コンポーネント説明
メーカー
ML9207 Datasheet PDF : 35 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
OKI Semiconductor
FEDL9207-02
ML9207-xx
Data Transfer Method and Command Write Method
Display control command and data are written by an 8-bit serial transfer.
Write timing is shown in the figure below.
Setting the CS pin to "Low" level enables a data transfer.
Data is 8 bits and is sequentially input into the DA pin from LSB (LSB first).
As shown in the figure below, data is read by the shift register at the rising edge of the shift clock, which is input
into the CP pin. If 8-bit data is input, internal load signals are automatically generated and data is written to each
register and RAM.
Therefore it is not necessary to input load signals from the outside.
Setting the CS pin to "High" disables data transfer. Data input from the point when the CS pin changes from
"High" to "Low" is recognized in 8-bit units.
CS
tDOFF
CP
tCSH
DA
B0 B1 B2 B3 B4 B5 B6 B7
LSB
MSB
1st byte
When data is written to DCRAM* Command and address data
B0 B1 B2 B3 B4 B5 B6 B7
LSB
MSB
2nd byte
Character code data
B0 B1 B2 B3 B4 B5 B6 B7
LSB
MSB
2nd byte
Character code data of the
next address
* When data is written to RAM (DCRAM, ADRAM, CGRAM) continuously, addresses are internally
incremented automatically.
Therefore it is not necessary to specify the 1st byte to write RAM data for the 2nd and later bytes.
Reset Function
Reset is executed when the RESET pin is set to "L", (when turning power on, for example) and initializes all
functions.
Initial status is as follows:
• Address of each RAM ......................................Address "00"H
• Data of each RAM............................................All contents are undefined
• General output port ..........................................All general output ports (P1 to P4) go "Low"
• Display digit.....................................................24 digits
• Brightness adjustment ......................................0/1024
• All display lights ON or OFF ...........................OFF mode
• Segment output ................................................All segment outputs (SEG1 to SEG35) go "Low"
• Common output................................................All common outputs (COM1 to COM24) go "Low"
• AD output ........................................................All AD outputs (AD1 to AD4) go "Low"
Please set the functions again according to "Setting Flowchart" after reset.
15/35