ELECTRICAL CHARACTERISTICS
DYNAMIC ELECTRICAL CHARACTERISTICS
DYNAMIC ELECTRICAL CHARACTERISTICS
Table 4. Dynamic Electrical Characteristics
Characteristics noted under conditions TA = 25°C, VM = 15 V, VDD = 5.0 V, GND = 0 V unless otherwise noted. Typical values
noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
INPUT (EN, IN1, IN2, GIN)
Pulse Input Frequency
Input Pulse Rise Time (11)
Input Pulse Fall Time (13)
fIN
–
–
200
kHz
tR
–
–
1.0
µs
(12)
tF
–
–
1.0
µs
(12)
OUTPUT
Propagation Delay Time
Turn-ON Time
Turn-ON Time
Turn-OFF Time
GOUT Output Delay Time (14)
Turn-ON Time
Turn-OFF Time
Charge Pump Circuit
Oscillator Frequency
Rise Time (15)
Low-Voltage Detection Time
Notes
11. Time is defined between 10% and 90%.
12. That is, the input waveform slope must be steeper than this.
13. Time is defined between 90% and 10%.
14. Load is 500 pF.
15. Time to charge CRES to 11 V after application of VDD.
µs
tPZH
–
0.3
1.0
tPLH
–
1.2
2.0
tPHL
–
0.5
1.0
µs
tTON
–
tTOFF
–
–
10
–
10
fOSC
100
200
400
kHz
tV
CRESON
–
0.1
1.0
ms
tVDDDET
–
–
10
ms
17510
6
Analog Integrated Circuit Device Data
Freescale Semiconductor