IC61SF25632T/D IC61SF25636T/D
IC61SF51218T/D
OPERATING RANGE
Range Ambient Temperature
Commercial 0°C to +70°C
Industrial
–40°C to +85°C
VCC
3.3V, +10%, –5%
3.3V, +10%, –5%
VCCQ
2.375–3.6V
2.375–3.6V
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter
Test Conditions
VOH
Output HIGH Voltage
IOH = –2.0 mA, VCCQ = 2.5V
IOH = –4.0 mA, VCCQ = 3.3V
VOL
Output LOW Voltage
IOL = 2.0 mA, VCCQ = 2.5V
IOL = 8.0 mA, VCCQ = 3.3V
VIH
Input HIGH Voltage
VCCQ = 2.5V
VCCQ = 3.3V
VIL
Input LOW Voltage
VCCQ = 2.5V
VCCQ = 3.3V
ILI
Input Leakage Current
ILO
Output Leakage Current
GND ≤ VIN ≤ VCC (1)
GND ≤ VOUT ≤ VCCQ, OE = VIH
Min. Max. Unit
1.7
—
V
2.4
—
V
—
0.7
V
—
0.4
V
1.7 VCCQ+ 0.3 V
2.0 VCCQ + 0.3 V
–0.3 0.7
V
–0.3 0.8
V
–2
2
µA
–2
2
µA
Notes:
1. The MODE, ZZ, XQ, pin14 pin has an internal pullup. and input leakage = ±10 µA .
POWER SUPPLY CHARACTERISTICS (Over Operating Range)
Parameter
Test Conditions
Symbol
AC Operating
Device Selected,
ICC1
Supply Current
All Inputs ≤ VIL or ≥VIH
OE = VIH, VCC = Max
f = 1/tKC
Clock Running Device Deselected,
ICC2
VCC = Max.,
All Inputs ≤ VIL or ≥VIH
f = 1/tKC
COMS Standby Device Deselected,
ISB
VCC = Max.,
All Inputs ≤ 0.2V or
≥VCC -0.2V; f = 0
Power Down Mode VCC = Max
Izz
ZZ ≥VCC - 0.2V
f = 0,
All input ≤ 0.2V or ≥VCC - 0.2V
Com.
Ind.
Com.
Ind.
Com.
Ind.
Com.
Ind.
-6.5
Max.
300
320
-7.5
Max.
290
310
-8.5
Max.
280
300
-9.5
Max. Unit
370 mA
290 mA
110 100 90
90 mA
120 110 100 100 mA
90
90
90
90 mA
100 100 100 100 mA
80
80
80
80 mA
90
90
90
90 mA
12
Integrated Circuit Solution Inc.
SSR020-0A 9/03/2002