28F008SA
EXTENDED TEMPERATURE OPERATING CONDITIONS
Symbol
Parameter
Notes Min Max Unit
TA
Operating Temperature
b40 a85 C
VCC
VCC Supply Voltage (10%)
5
4 50 5 50 V
VCC
VCC Supply Voltage (5%)
5
4 75 5 25 V
DC CHARACTERISTICS EXTENDED TEMPERATURE OPERATION
Symbol
Parameter
Notes Min Typ Max Unit
Test Condition
ILI
Input Load Current
1
ILO
Output Leakage Current
1
ICCS
VCC Standby Current
13
ICCD
VCC Deep PowerDown
1
Current
ICCR
VCC Read Current
1
g1 0 mA VCC e VCC Max
VIN e VCC or GND
g10 mA VCC e VCC Max
VOUT e VCC or GND
1 0 2 0 mA VCC e VCC Max
CE e RP e VIH
30 100 mA VCC e VCC Max
CE e RP e VCC g0 2V
0 20 20
mA RP e GND g0 2V
IOUT (RY BY ) e 0 mA
20 35 mA VCC e VCC Max CE e GND
f e 8 MHz IOUT e 0 mA
CMOS Inputs
25 50 mA VCC e VCC Max CE e VIL
f e 8 MHz IOUT e 0 mA
TTL Inputs
ICCW
ICCE
ICCES
VCC Byte Write Current
1
VCC Block Erase Current
1
VCC Erase Suspend Current 1 2
IPPS
VPP Standby Current
1
IPPD
VPP Deep PowerDown
1
Current
10 30 mA Byte Write In Progress
10 30 mA Block Erase In Progress
5 10 mA Block Erase Suspended
CE e VIH
g1 g15 mA VPP s VCC
0 10 5 0 mA RP e GND g0 2V
IPPR
VPP Read Current
IPPW
VPP Byte Write Current
1
200 mA VPP l VCC
10 30 mA VPP e VPPH
Byte Write in Progress
IPPE
VPP Block Erase Current
1
10 30 mA VPP e VPPH
Block Erase in Progress
IPPES
VPP Erase Suspend
Current
1
90 200 mA VPP e VPPH
Block Erase Suspended
21