DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NJU6677 データシートの表示(PDF) - Japan Radio Corporation

部品番号
コンポーネント説明
メーカー
NJU6677
JRC
Japan Radio Corporation  JRC
NJU6677 Datasheet PDF : 45 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
NJU6677
(3-4) Column Address
When MPU accesses the Display Data RAM, the page address (refer(3-3) ) and column address set are
required before the data writing. The column address set requires twice address set which are higher order 4
bits address set and lower order 4 bits. When the MPU accesses the Display Data RAM sequentially, the
column address is increase one by one automatically, therefore, the MPU can access only the data sequen-
tially without address set.
After writing 1page data, page address setting is required due to page address doesn't increase automatically.
The increment of the column address is stopped at the address of (83)H automatically, and the page address is
not changed even if the column address increase to (83)H and stop. In this time the page address is not
changed.
R /W
A0 RD WR D7
D6
D5
D4
D3
D2
D1
D0
0
1
0
0
0
0
1
A 7 A 6 A 5 A 4 Higher Order
0
1
0
0
0
0
0
A3 A2 A1 A0 Lower Order
A7 A6 A5 A4 A3 A2 A1 A0
00000000
00000001
:
:
10000011
Column Address(HEX)
0
1
:
:
83
(3-5) Status Read
This instruction reads out the internal status of "BUSY", “ADC", "ON/OFF" and "RESET".
R /W
A0 RD WR D7
D6
D5
D4
D3
D2
D1
D0
0
0
1 BUSY ADC ON/OFF RESET 0
0
0
0
BUSY : BUSY=1 indicate the operating or the Reset cycle.
The instruction can be input after the BUSY status change to "0".
ADC : Indicate the output correspondence of column (segment) address and segment driver.
0 :Counterclockwise Output (Inverse) Column Address 131-n <---> Segment Driver n
1 :Clockwise Output
(Normal) Column Address n <---> Segment Driver n
(Note) The data "0=Inverse" and "1=Normal" of ADC is inverted with the ADC select
Instruction of "1=Inverse" and "0=Normal".
ON/OFF : Indicate the whole display On/Off status.
0 : Whole Display "On
1 : Whole Display "Off"
(Note) The data "0=On" and "1=Off" of Display On/Off status read out is inverted with the
Display On/Off instruction data of "1=On" and "0=Off".
RESET : Indicate the initializing by RES signal or reset instruction.
0:
-
1 : Initialization Period

Share Link: 