INFRAED REMOCON RECEIVER
S5G9801X01/S5G9803X01
6. EXPLANATION OF OUTPUT PULSE SP, CP, TP
1) SP1 - SP10 (Single Pulse)
When a single key is depressed, after checking the 12-bit receiving data, if the data agree, a single pulse is output.
The output is raised from “L” level to “H” level and returned again to “L” level after about 107 msec.
KEY ON
Single Signal
Latch Pulse
Single Output
12Bits
12Bits
About 107 msec
Figure 8.
2) CP1 - CP6 (Continuous Pulse)
Continuous pulse is output by the first latch pulse after key ON. Output is kept at “H” level as a long as a continuous
signal is input.
When the key is released and continuous signal is stopped about 160 msec later, output is reversed to “L” level by
the last latch pulse.
Further, CP1 - CP6 are able to output simultaneously in parallel method, maximum sextet outputs at “H” level by
continuous signals sent from the transmitter.
These outputs are optimum as outputs of REC-PLAY, REC-PAUSE and CUE/REVIEW of a tape deck.
KEY ON
Continuous
Signal
Latch Pulse
Continuous
Output
12
12
Figure 9.
3) TP1, TP2 (Toggle Pulse)
When toggle signal is received, toggle pulse output is reversed.
This toggle pulse is used for power ON, OFF, MUTE, etc.
160msc
KEY ON
Toggle signal
12
12
Latch Pulse
Toggle Output
Figure 10.
9