AUTOMOTIVE 8XC196KB
Parameter
Resolution
Absolute Error
Full Scale Error
Zero Offset Error
Non-Linearity
Differential Non-Linearity
Channel-to-Channel Matching
Repeatability
Temperature Coefficients
Offset
Full Scale
Differential Non-Linearity
Off Isolation
Feedthrough
VCC Power Supply Rejection
Input Resistance
DC Input Leakage
Sample Time (Prescaler on off)
Input Capacitance
Typical (1)
0 25 g0 5
b0 25 g0 5
15g25
g0 1
g0 25
0 009
0 009
0 009
b60
b60
15 8
3
Minimum
512
9
0
0
lb1
0
b60
1K
0
Maximum
1024
10
g6
g4
a2
g1
5K
3
Units
Level
Bits
LSBs
LSBs
LSBs
LSBs
LSBs
LSBs
LSBs(1)
LSB C(1)
LSB C(1)
LSB C(1)
dB(1 2 4)
dB(1 2)
dB(1 2)
X(1)
mA
States (3)
pF
NOTES
These values are expected for most parts at 25 C but are not tested or guaranteed
An ‘‘LSB’’ as used here has a value of approximately 5 mV (See Automotive Handbook for A D glossary of terms
1 These values are not tested in production and are based on theoretical estimates and or laboratory test
2 DC to 100 KHz
3 One state e 125 ns 16 MHz 333 ns 6 MHz
4 Multiplexer Break-Before-Make Guaranteed
80C196KB FUNCTIONAL DEVIATIONS
The 80C196KB has the following problems
1 The HSI unit has two errata one dealing with res-
olution and the other with first entries into the
FIFO
The HSI resolution is 9 states instead of 8 states
Events on the same line may be lost if they occur
faster than once every 9 state times
There is a mismatch between the 9 state time HSI
resolution and the 8 state time timer This causes
one time value to be unused every 9 timer counts
Events may receive a time-tag one count later
than expected because of this ‘‘skipped’’ time val-
ue
If the first two events into an empty FIFO (not
including the Holding Register) occur in the same
internal phase both are recorded with one time-
tag Otherwise if the second event occurs within
9 states after the first its time-tag is one count
later than the first’s If this is the ‘‘skipped’’ time
value the second event’s time-tag is 2 counts lat-
er than the first’s
If the FIFO and Holding Register are empty the
first event will transfer into the Holding Register
after 8 state times leaving the FIFO empty again
If the second event occurs after this time it will
act as a new first event into an empty FIFO
2 If an A D conversion in progress is aborted by
starting a new A D conversion results of the sec-
ond conversion may be inaccurate