DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SST49LF008A-33-4C-WH データシートの表示(PDF) - Silicon Storage Technology

部品番号
コンポーネント説明
メーカー
SST49LF008A-33-4C-WH
SST
Silicon Storage Technology SST
SST49LF008A-33-4C-WH Datasheet PDF : 36 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
2 Mbit / 3 Mbit / 4 Mbit / 8 Mbit Firmware Hub
SST49LF002A / SST49LF003A / SST49LF004A / SST49LF008A
Advance Information
TABLE 9: OPERATION MODES SELECTION (PP MODE)
Mode
RST#
OE#
WE# DQ
Address
Read
Program
Erase
VIH
VIL
VIH
DOUT
VIH
VIH
VIL
DIN
VIH
VIH
VIL
X1
AIN
AIN
Sector or Block address,
XXH for Chip-Erase
Reset
VIL
X
X
High Z
X
Write Inhibit
VIH
VIL
X
High Z/DOUT
X
X
VIH
High Z/DOUT
X
Product Identification
VIH
VIL
VIH
Manufacturer’s ID (BFH) A18-A1=VIL, A0=VIL
Device ID2
A18-A1=VIL, A0=VIH
1. X can be VIL or VIH, but no other value.
2. Device ID 57H for SST49LF002A, 1BH for SST49LF003A, 60H for SST49LF004A, and 5AH for SST49LF008A
T9.4 504
TABLE 10: SOFTWARE COMMAND SEQUENCE
Command Sequence
1st1
Write Cycle
2nd1
Write Cycle
3rd1
Write Cycle
4th1
Write Cycle
5th1
Write Cycle
6th1
Write Cycle
Byte-Program
Sector-Erase
Block-Erase
Chip-Erase6
Software ID Entry7,8
Software ID Exit9
Software ID Exit9
Addr2
5555H
5555H
5555H
5555H
5555H
XXH
5555H
Data
AAH
AAH
AAH
AAH
AAH
F0H
AAH
Addr2
2AAAH
2AAAH
2AAAH
2AAAH
2AAAH
2AAAH
Data Addr2
55H 5555H
55H 5555H
55H 5555H
55H 5555H
55H 5555H
55H 5555H
Data Addr2
A0H BA3
80H 5555H
80H 5555H
80H 5555H
90H
F0H
Data
Data
AAH
AAH
AAH
Addr2
2AAAH
2AAAH
2AAAH
Data Addr2
55H SAX4
55H BAX5
55H 5555H
Data
30H
50H
10H
T10.5 504
1. FWH Mode uses consecutive Write cycles to complete a command sequence; PP Mode uses consecutive bus cycles to complete a
command sequence.
2. Address format A14-A0 (Hex), Addresses A15-A21 can be VIL or VIH, but no other value, for the Command sequence in PP Mode.
3. BA = Program Byte address
4. SAX for Sector-Erase Address
5. BAX for Block-Erase Address
6. Chip-Erase is supported in PP Mode only
7. SST Manufacturer’s ID = BFH, is read with A0=0,
With A17-A1 = 0; 49LF002A Device ID = 57H, is read with A0 = 1.
With A18-A = 0; 49LF003A Device ID = 1BH, is read with A0 = 1.
With A18-A1 = 0; 49LF004A Device ID = 60H, is read with A0 = 1.
With A19-A1 = 0; 49LF008A Device ID = 5AH, is read with A0 = 1.
8. The device does not remain in Software Product ID mode if powered down.
9. Both Software ID Exit operations are equivalent
©2001 Silicon Storage Technology, Inc.
18
S71161-06-000 9/01 504

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]