NXP Semiconductors
TDA8024
Standard smart card interface
CMDVCC LOW within a card session. Output OFF goes LOW when a fault
condition is detected. As soon as this occurs, an emergency deactivation is performed
automatically (see Figure 11). When the system controller resets CMDVCC to HIGH it
may sense the OFF level again after completing the deactivation sequence. This
distinguishes between a hardware problem or a card extraction (OFF goes HIGH
again if a card is present).
Depending on the type of card-present switch within the connector (normally-closed or
normally-open) and on the mechanical characteristics of the switch, bouncing may occur
on the PRES signals at card insertion or withdrawal.
There is a debounce feature in the device with an 8 ms typical duration (see Figure 10).
When a card is inserted, output OFF goes HIGH only at the end of the debounce time.
When the card is extracted, an automatic deactivation sequence of the card is performed
on the first true/false transition on PRES or PRES and output OFF goes LOW.
35(6
2))
&0'9&&
9&&
GHERXQFH
GHERXQFH
GHDFWLYDWLRQFDXVHGE\
FDUGVZLWKGUDZDO
GHDFWLYDWLRQFDXVHGE\
VKRUWFLUFXLW
DDD
See “Application note AN10141” for software decision algorithm on OFF signal.
Fig 10. Behavior of OFF, CMDVCC, PRES and VCC.
TDA8024
Product data sheet
2))
35(67
567
&/.
,2
9&&
983
W W W
W
WGH
W
Fig 11. Emergency deactivation sequence (card extraction)