Philips Semiconductors
Fault-tolerant CAN transceiver
TEST AND APPLICATION INFORMATION
Preliminary specification
TJA1054
handbook, full pagewidth
+5 V
INH
BAT
VCC
WAKE
1
7
14
10
RTH
R1
8
TXD
2
STB
5
EN
6
TJA1054
CANL
12
CANH
11
RXD
3
20 pF
13
GND
RTL
9
4
R1
ERR
C1
C2
C1
MGL423
For testing, the 100 Ω termination resistors are not connected to RTH or RTL because minimum 500 Ω per transceiver is allowed.
Fig.5 Test circuit for dynamic characteristics.
handbook, full pagewidth
+12 V
+5 V
10 µF
WAKE
7
TXD
2
STB
5
EN
6
RXD
3
20 pF
INH
1
BAT
14
VCC
10
RTH
8
125 Ω
CANL
12
511 Ω
TJA1054
CANH
11
511 Ω
RTL
9
13
4
125 Ω
GND
ERR
1 nF
1 nF
1 nF
1 nF
GENERATOR
MGL426
The waveforms of the applied transients will be in accordance with ISO 7637 part 1, test pulses 1, 2, 3a and 3b.
Fig.6 Test circuit for automotive transients.
1999 Feb 11
15