UEI25 Series
Single Output Isolated 25-Watt DC/DC Converters
FUNCTIONAL SPECIFICATIONS (CONT.) – MODEL UEI25-120-D48
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Output Voltage Range
Overvoltage Protection
Current
Output Current Range
Minimum Load ➂
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short for
recovery)
Short circuit protection method
Regulation ➄
Line Regulation
Load Regulation
Ripple and Noise
Temperature Coefficient
Maximum Capacitive Loading (10% ceramic,
90% Oscon)
MECHANICAL (Through Hole Models)
Outline Dimensions (no baseplate)
(Please refer to outline drawing)
Weight
Conditions ➀ ➂
See Derating
No trim
At 50% load
User-adjustable
Via magnetic feedback
97% of Vnom., after warmup
Hiccup technique, autorecovery within ±1.25%
of Vout
Output shorted to ground, no damage
Current limiting
Vin=min. to max., Vout=nom., 50% load
Iout=min. to max., Vin=48V
5 Hz- 20 MHz BW
At all outputs
Cap. ESR=<0.02Ω, full resistive load
Conditions ➀
C75 case
WxLxH
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
Radiated, EN55022/CISPR22
Relative humidity, non-condensing
Altitude
Nickel subplate
Gold overplate
With derating, 200 LFM
Vin = Zero (no power)
Measured at hotspot
External filter is required
To +85°C
must derate -1%/1000 feet
RoHS rating
Minimum
0.0
11.88
-1
-10
14
0.0
2.3
0
Minimum
-40
-55
130
10
-500
-152
Typical/Nominal
25.2
12.00
19
2.1
No minimum load
3
Continuous
95
0.02
Typical/Nominal
0.96x1.1x0.32
24.38x27.94x8.13
0.32
9.07
0.04
1.016
Copper alloy
50
5
135
B
B
RoHS-6
Maximum
25.45
12.12
+1
+10
22
2.1
3.4
0.1
Units
W
Vdc
% of Vset.
% of Vnom.
Vdc
A
A
A
±0.075
±0.05
120
470
Maximum
85
125
150
90
10,000
3048
% of Vout
% of Vout
mV pk-pk
% of Vnom./°C
μF
Units
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
°C
°C
°C
Class
Class
%RH
feet
meters
Notes
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal out-
put voltage and full load. General conditions are +25˚ Celsius ambient temperature,
near sea level altitude, natural convection airflow. All models are tested and specified
with external parallel 1 μF and 10 μF multi-layer ceramic output capacitors. The ex-
ternal input capacitor is 4.7 μF ceramic. All capacitors are low-ESR types wired close
to the converter. These capacitors are necessary for our test equipment and may not
be needed in the user's application.
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth.
Input filtering is Cbus=220 μF, Cin=33 μF and Lbus=12 μH.
➂ All models are stable and regulate to specification under no load.
➃ The Remote On/Off Control is referred to -Vin.
➄ Regulation specifications describe the output voltage changes as the line voltage or
load current is varied from its nominal or midpoint value to either extreme.
www.murata-ps.com
MDC_UEI25W.B03 Page 8 of 23