W742C814
SEF.0 = 1
SEF.1 = 1
SEF.2 = 1
SEF.3 = 1
Device will exit stop mode when falling edge signal is applied to pin RC.0
Device will exit stop mode when falling edge signal is applied to pin RC.1
Device will exit stop mode when falling edge signal is applied to pin RC.2
Device will exit stop mode when falling edge signal is applied to pin RC.3
6.14 Hold Mode Operation
In hold mode, all operations of the µC cease, except for the operation of the oscillator, Timer, Divider,
LCD driver, DTMF generator and MFP generator. The µC enters hold mode when the HOLD
instruction is executed. The hold mode can be released in one of five ways: by the action of timer 0,
timer 1, divider 0, divider 1, the RC port. Before the device enters the hold mode, the HEF, PEF, and
IEF flags must be set to define the hold mode release conditions. For more details, refer to the
instruction-set table and the following flow chart.
Divider 0, Divider 1, Timer
0, Timer 1, Signal Change
at RC Port
Yes
Interrupt
Enable?
Yes
IEF
Flag Set?
Yes
No
No
In
No
HOLD
Mode?
No
Interrupt
Enable?
Yes
IEF
No
Flag Set?
Yes
Reset EVF Flag
Execute
Interrupt Service Routine
(Note)
HEF
Flag Set?
Reset EVF Flag
Execute
Interrupt Service Routine
No
Yes
(Note)
Disable interrupt
Disable interrupt
HOLD
PC <- (PC+1)
Note: The bit of EVF corresponding to the interrupt signal will be reset.
Figure 6-9 Hold Mode and Interrupt Operation Flow Chart