Preliminary W91031
CPE goes off-hook
CPE mutes handset & disables keypad
Tip/Ring
CAS
CPE sends
ACK
Mark
Note 1
SLEEP
A
B
C
D
E
Note 5
INTN
tREC
tABS
ALGO
CPE unmutes handset
and enables keypad
Message
F
G
...
FSKE
FCDN
Note 2
Note 3
Note 4
FDRN
DCLK
DATA
...
Data
Figure 9-4. Input and Output Timing of Bellcore Off-hook Data Transmission
A = 7585 mS
C = 5565 mS
E = 5875 mS
G 50 mS
B = 0100 mS
D = 0500 mS
F = Depends on data length
Notes:
1. In a CPE where AC power is not available, the designer may choose to switch over to line power when the CPE goes
off-hook and use battery power while on-hook.
2. The FSKE pin should be set low to enable the alert tone detector when the dual tone alert signal is expected. The CPE has
the capability to disable the CAS detection by setting FSKE always high during the on-hook state.
3. FSKE may be set high as soon as the CPE has finished sending the acknowledge signal ACK.
4. FSKE should be set low when FCDN has become inactive.
5. For unsuccessful attempts where the end office does not send the FSK signal, the CPE should disable FSKE, unmute the
handset and enable the keypad after this interval has elapsed.