M54640P
Recommended Operating Condition
Parameter
Supply voltage
Output supply voltage
Output current
Logic input rise time
Logic input fall time
Thermal shutdown temperature
Symbol
VCC
VMM
IO
tPLH
tPHL
TON
Limits
Min.
4.75
10
20
(Ta = 25°C, unless otherwise noted.)
Typ.
Max.
Unit
5
5.25
V
40
V
800
mA
2
µS
2
µS
175
°C
Electrical characteristics
Parameter
Logic input voltage “H”
“L”
Comparator threshold
Comparator input current
Output cutoff current
Saturation voltage
Cutoff time
Turnoff delay
Supply current
Logic input current “H”
“L”
Symbol
V
IH
VIL
VCH
VCM
VCL
ICO
I
OFF
Vsat
Limits
Min.
2.0
0
400
240
75
−20
Typ.
430
260
90
tOFF
25
30
td
1.6
ICC
I
IH
I
IL
(Ta = 25°C, VCC = 5.0V, unless otherwise noted.)
Max.
V
CC
0.8
450
280
100
20
100
4.0
Unit
V
mV
µA
µA
V
35
µS
2.0
µS
25
mA
20
µA
−0.4 mA
Test conditions
V =5V
CC
VR=5V, I0=I1=0
VR=5V, I0=1,I1=0
VR=5V, I0=0, I1=1
I0=I1=1(Ta=25°C)
The voltage at the sensing resistor is
not included. IO=500mA
VMM=10V, tON ≥ 5µs
Ta=25°C, dVK/dt ≥ 50mV/µs
VCC=5V
V =2.4V
I
V =0.4V
I
Rev.1.0, Sep.19.2003, page 3 of 9