MITSUBISHI STORAGE CARD
Preliminary
AC ELECTRICAL CHARACTERISTICS
CompactFlash CARDS
MEMORY TIMING
Read Cycle[Attribute] (Ta=0~60°C, VCC=5V±10% or VCC=3.3V±5% unless otherwise noted)
Symbol
tcR
ta(A)
ta(CE)
ta(OE)
tdis(CE)
tdis(OE)
ten(CE)
ten(OE)
tV(A)
Parameter
Read cycle time
Address access time
Card enable access time
Output enable access time
Output disable time (from CE)
Output disable time (from OE)
Output enable time (from CE)
Output enable time (from OE)
Data valid time (after address change)
Limits
Min.
Typ.
Max.
Unit
300
ns
300
ns
300
ns
150
ns
100
ns
100
ns
5
ns
5
ns
0
ns
Read Cycle[Common] (Ta=0~60°C, VCC=5V±10% or VCC=3.3V±5% unless otherwise noted)
Limits
Symbol
Parameter
Min.
Typ.
Max.
Unit
tcR
Read cycle time
250
ns
ta(A)
Address access time
250
ns
ta(CE)
Card enable access time
250
ns
ta(OE)
Output enable access time
125
ns
tdis(CE) Output disable time (from CE)
100
ns
tdis(OE) Output disable time (from OE)
100
ns
ten(CE) Output enable time (from CE)
5
ns
ten(OE) Output enable time (from OE)
5
ns
tV(A)
Data valid time after address change
0
ns
MITSUBISHI
ELECTRIC
23
Oct.1999. Rev. 0.2