DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M36W432BG85ZA6 データシートの表示(PDF) - STMicroelectronics

部品番号
コンポーネント説明
メーカー
M36W432BG85ZA6 Datasheet PDF : 66 Pages
First Prev 51 52 53 54 55 56 57 58 59 60 Next Last
M36W432TG, M36W432BG
Figure 27. Quadruple Word Program Flowchart and Pseudo Code
Start
Write 56h
Write Address 1
& Data 1 (3)
Write Address 2
& Data 2 (3)
Write Address 3
& Data 3 (3)
Write Address 4
& Data 4 (3)
Read Status
Register
quadruple_word_program_command (addressToProgram1, dataToProgram1,
addressToProgram2, dataToProgram2,
addressToProgram3, dataToProgram3,
addressToProgram4, dataToProgram4)
{
writeToFlash (any_address, 0x56) ;
writeToFlash (addressToProgram1, dataToProgram1) ;
/*see note (3) */
writeToFlash (addressToProgram2, dataToProgram2) ;
/*see note (3) */
writeToFlash (addressToProgram3, dataToProgram3) ;
/*see note (3) */
writeToFlash (addressToProgram4, dataToProgram4) ;
/*see note (3) */
/*Memory enters read status state after
the Program command*/
do {
status_register=readFlash (any_address) ;
/* EF or GF must be toggled*/
NO
b7 = 1
YES
NO
b3 = 0
YES
NO
b4 = 0
YES
NO
b1 = 0
YES
End
} while (status_register.b7== 0) ;
VPPF Invalid
Error (1, 2)
if (status_register.b3==1) /*VPPF invalid error */
error_handler ( ) ;
Program
Error (1, 2)
if (status_register.b4==1) /*program error */
error_handler ( ) ;
Program to Protected
Block Error (1, 2)
if (status_register.b1==1) /*program to protect block error */
error_handler ( ) ;
}
AI07934
Note: 1. Status check of b1 (Protected Block), b3 (VPPF Invalid) and b4 (Program Error) can be made after each program operation or after
a sequence.
2. If an error is found, the Status Register must be cleared before further Program/Erase operations.
3. Address 1 to Address 4 must be consecutive addresses differing only for bits A0 and A1.
57/66

Share Link: 