Philips Semiconductors
HITAG proximity evaluation kit
Product specification
HTEV400
Software start-up
SYSTEM REQUIREMENTS
In order to use the RFIDDEMO software the following
system requirements must be satisfied:
• IBM-PC or compatible (minimum 286 processor)
• 640 kbyte RAM
• Serial interface.
INSTALLATION
1. Create a new directory on your PC for the demo-files
e.g. C:\RFIDDEMO
2. Copy all the files from the CD-ROM into the new
directory.
STARTING THE DEMO-PROGRAM
We strongly recommend to carefully read the user manual
“RFIDDEMO HITAG evaluation software” before starting
the demo system. Inconsiderate use of individual menu
options may result in unwanted irreversible changes in
access rights.
Start your demo-program by typing the command
RFIDDEMO.EXE.
CHARACTERISTICS
DEVICE
PARAMETER
External power supply DC voltage: 9 to 16 V
unit
DC current: 150 mA
(maximum)
Read and write device interface: RS232
operating frequency: 125 kHz
Operating temperature 0 to 70 °C
REFERENCE DOCUMENTS
CATEGORY
User manual
Data sheet
Data sheet
TITLE
“RFIDDEMO HITAG evaluation
software”
“HTCM400 HITAG core
module”
“HTRM440 HITAG proximity
reader module”
2001 Sep 24