DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6874 データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX6874 Datasheet PDF : 40 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
EEPROM-Programmable, Hex/Quad,
Power-Supply Sequencers/Supervisors
Table 1. Programmable Features (continued)
FEATURE
Manual Reset Input
(MR)
Write Disable
Configuration Lock
DESCRIPTION
Forces PO_ into the active output state when MR = GND
PO_ deassert after MR releases high and the PO_ timeout period expires
PO_ cannot be a function of MR only
Locks user EEPROM based on PO_
Locks configuration EEPROM
High-Voltage Input (IN1)
IN1 offers threshold voltages of +2.5V to +13.2V in
50mV increments, or +1.25V to +7.625V in 25mV incre-
ments. Use the following equations to set the threshold
voltages for IN1:
x = VTH 2.5V for + 2.5V to + 13.2V range
0.05V
x = VTH 1.25V for + 1.25V to + 7.625V range
0.025V
where VTH is the desired threshold voltage and x is the
decimal code for the desired threshold (Table 2). For
the +2.5V to +13.2V range, x must equal 214 or less,
otherwise the threshold exceeds the maximum operat-
ing voltage of IN1.
IN2
IN2 offers thresholds from +2.5V to +5.5V in 50mV
increments, or +1.25V to +3.05V in 25mV increments.
Use the following equations to set the threshold volt-
ages for IN2:
x = VTH 2.5V for + 2.5V to + 5.5V range
0.05V
x = VTH 1.25V for + 1.25V to + 3.05V range
0.025V
where VTH is the desired threshold voltage and x is the
decimal code for the desired threshold (Table 3).
For the +2.5V to +5.5V range, x must equal 60 or less,
otherwise the threshold exceeds the maximum operat-
ing voltage of IN2. For the +1V to +3.05V range, x must
equal 72 or less.
IN3–IN6
IN3–IN6 offer positive voltage detectors monitor volt-
ages from +1V to +5.5V in 20mV increments, or +0.5V
to +3.05V in 10mV increments. Use the following equa-
tions to set the threshold voltages for IN_:
x = VTH 1V for + 1V to + 5.5V range
0.02V
x = VTH 0.5V for + 0.5V to + 3.05V range
0.01V
where VTH is the desired threshold voltage and x is the
decimal code for the desired threshold (Table 4). For
the +1V to +5.5V range, x must equal 225 or less, oth-
erwise the threshold exceeds the maximum operating
voltage of IN3–IN6.
______________________________________________________________________________________ 13

Share Link: 