DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AN78L04M データシートの表示(PDF) - Panasonic Corporation

部品番号
コンポーネント説明
メーカー
AN78L04M Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AN78Lxx/AN78LxxM Series
I Basic Regulator Circuit
Input
1
2
AN78Lxx
CI
3
Output
CO
CI is necessary when the input line is long.
CO improves the transient response.
I Usage Notes
1. Cautions for a basic circuit
Di
VI
CI
1
3
2
VO
CO
Figure 1
CI: When a wiring from a smoothing circuit to a three-pin regulator
is long, it is likely to oscillate at output. A capacitor of 0.1µF to
0.47µF should be connected near an input pin.
CO: When any sudden change of load current is likely to occur,
connect an electrolytic capacitor of 10µF to 100µF to improve a
transitional response of output voltage.
Di: Normally unnecessary. But add it in the case that there is a
residual voltage at the output capacitor Co even after switching
off the supply power because a current is likely to flow into an
output pin of the IC and damage the IC.
2. Other caution items
1) Short-circuit between the input pin and GND pin
If the input pin is short-circuitted to GND or is cut
off when a large capacitance capacitor has been con-
nected to the IC's load, a voltage of a capacitor con-
nected to an output pin is applied between input/out-
put of the IC and this likely results in damage of the
IC. It is necessary, therefore, to connect a diode, as
shown in figure 2, to counter the reverse bias between
input/output pins.
2) Floating of GND pin
1
In
2
GND
3
Out
+
出力
CO
Figure 2
If a GND pin is made floating in an operating mode, an unstabilized input voltage is outputted. In this case, a
thermal protection circuit inside the IC does not normally operate. In this state, if the load is short-circuited or
overloaded, it is likely to damage the IC.
I Application Circuit Examples
VI
Q1
20
0.33µF
1
2
AN78Lxx
3
VI
IO
VO
1
2
AN78Lxx
3
VO'
VO
R2
0.1µF
IBias
VO = VO' + IBias + VRO2' R1
R1
Note) VO varies due to sample to sample variation of IBias .
Never fail to adjust individually with R1 .
10
SFF00005CEB