MITSUBISHI SEMICONDUCTOR <Intelligent Power Module>
PS21244-E
TRANSFER-MOLD TYPE
INSULATED TYPE
THERMAL RESISTANCE
Symbol
Parameter
Rth(j-c)Q
Rth(j-c)F
Rth(c-f)
Junction to case thermal
resistance
Contact thermal resistance
Condition
Inverter IGBT part (per 1/6 module)
Inverter FWD part (per 1/6 module)
Case to fin, (per 1 module)
thermal grease applied
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Collector-emitter saturation
voltage
FWD forward voltage
Switching times
Collector-emitter cut-off
current
Condition
VD = VDB = 15V
IC = 15A, Tj = 25°C
VCIN = 0V
IC = 15A, Tj = 125°C
Tj = 25°C, –IC = 15A, VCIN = 5V
VCC = 300V, VD = VDB = 15V
IC = 15A, Tj = 125°C, VCIN = 5V ↔ 0V
Inductive load (upper-lower arm)
VCE = VCES
Tj = 25°C
Tj = 125°C
Limits
Min.
Typ.
Max. Unit
—
—
2.85 °C/W
—
—
4.5 °C/W
—
—
0.067 °C/W
Limits
Min.
Typ.
Max. Unit
—
1.55 2.15
—
1.65 2.25
V
—
2.50 3.40
V
0.10
0.70
1.20
µs
—
0.10
—
µs
—
0.40
0.80
µs
—
1.50
2.60
µs
—
0.90
1.80
µs
—
—
1
—
—
mA
10
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
Limits
Unit
Min. Typ. Max.
VD
Control supply voltage
Applied between VP1-VPC, VN1-VNC
13.5 15.0
16.5
V
VDB
Control supply voltage
Applied between VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
13.5 15.0
16.5
V
ID
VFOH
VFOL
Circuit current
Fault output voltage
VD = 15V, VCIN= 5V Total of VP1-VPC, VN1-VNC
—
VDB = 15V
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS —
—
—
8.50
mA
1.00
VSC = 0V, FO = 10kΩ 5V pull-up
4.9
—
—
V
VSC = 1V, FO = 10kΩ 5V pull-up
—
0.8
1.2
V
VFOsat
VSC = 1V, IFO = 15mA
0.8
1.2
1.8
V
tdead
Arm shoot-through blocking time
Relates to corresponding input signal for blocking arm
shoot-through.
–20°C ≤ TC ≤ 100°C
2.5
—
—
µs
VSC(ref)
UVDBt
Short circuit trip level
Tj = 25°C, VD = 15V
Trip level
(Note 3) 0.45
0.5
0.55
V
10.0
—
12.0
V
UVDBr
UVDt
Supply circuit under-voltage
protection
Tj ≤ 125°C
Reset level
Trip level
10.5
—
12.5
V
10.3
—
12.5
V
UVDr
Reset level
10.8
—
13.0
V
tFO
Fault output pulse width
CFO = 22nF
(Note 4) 1.0
1.8
—
ms
Vth(on)
Vth(off)
ON threshold voltage
OFF threshold voltage
Applied between : UP, VP, WP-VPC, UN, VN, WN-VNC
0.8
1.4
2.0
V
2.5
3.0
4.0
V
Note 3 : Short circuit protection is functioning only at the low-arms. Please select the value of the external shunt resistor such that the SC trip-
level is less than 25.5 A.
4 : Fault signal is output when the low-arms short circuit or control supply under-voltage protective functions operate. The fault output pulse-
width tFO depends on the capacitance value of CFO according to the following approximate equation : CFO = 12.2 ✕ 10-6 ✕ tFO [F].
Sep. 2001