MP02X130 Series
600
0.15 0.12 0.10 0.08
500
0.20
0.04 0.02 Rth(hs-a) ˚C/W
400
R - Load
L - Load
300
0.30
200
0.40
100
0
0
20
40
60
80
100
0 20 40 60 80 100 120 140 160 180 200
Maximum ambient temperature - (˚C)
D.C. output current - (A)
Fig. 11 50/60Hz single phase bridge dc output current vs power loss and maximum permissible ambient temperature for
various values of heatsink thermal resistance
(Note: Rth(hs-a) values given above are true heatsink thermal resistances to ambient and already account for Rth(c-hs) module contact thermal)
600
0.15 0.12 0.10 0.08
500
0.20
400
0.30
300
0.40
0.04 0.02 Rth(hs-a) ˚C/W
R & L- Load
200
100
0
0
20
40
60
80
100
0 20 40 60 80 100 120 140 160 180 200
Maximum ambient temperature - (˚C)
D.C. output current - (A)
Fig. 12 50/60Hz 3- phase bridge dc output current vs power loss and maximum permissible ambient temperature for
various values of heatsink thermal resistance
(Note: Rth(hs-a) values given above are true heatsink thermal resistances to ambient and already account for Rth(c-hs) module contact thermal)
6/8