M41T11
5
DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Table 5:
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Table 5. Operating and AC measurement conditions(1)
Parameter
M41T11
Supply voltage (VCC)
Ambient operating temperature (TA)
Load capacitance (CL)
Input rise and fall times
2.0 to 5.5(2)
–40 to 85
100
≤ 50
Input pulse voltages
0.2VCC to 0.8VCC
Input and output timing ref. voltages
0.3VCC to 0.7VCC
1. Output Hi-Z is defined as the point where data is no longer driven.
2. Supply voltage for SOH28 is 3.3 V to 5.5 V.
Unit
V
°C
pF
ns
V
V
Figure 14. AC testing input/output waveform
0.8VCC
0.2VCC
0.7VCC
0.3VCC
AI02568
Doc ID 6103 Rev 10