[AKD4712-A]
■ Operation Screen
1. Start up the control program following the above procedure.
2. After power is supplied to the evaluation board, AK4712 must be reset once by bringing SW2 (AK4712-PDN) from
“L” to “H”.
3. The control program operation screen is shown below
Figure 2. Control program window
■ Operation Overview
Register map and testing are controlled by this control software. These controls may be selected by the upper tabs.
Frequently used buttons, such as the register initializing button “Write Default”, are located outside of the switching tab
window. Refer to the “■ Dialog Box” section for details of each dialog box setting.
■ Button Functions
1. [Port Reset]: Reset connection to PC
Click this button after the control software starts up and the evaluation board is connected to the PC via USB cable.
2. [Write Default]: Register Initialization
<KM111300>
-6-