Common Electrical Specifications ISL60002 -10, -11, -12, -18, -20, and -25 Operating conditions:
VIN = 3.0V, IOUT = 0mA, COUT = 0.001µF, TA = -40 to +85°C, unless otherwise specified. Boldface limits apply across the operating temperature range,
-40°C to +85°C.
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
(Note 11) TYP (Note 11)
UNIT
Output Voltage Temperature Coefficient
(Note 12)
TC VOUT
20
ppm/°C
Supply Current
Line Regulation
Load Regulation
Thermal Hysteresis (Note 13)
Long Term Stability (Note 14)
Short-Circuit Current (to GND) (Note 15)
Output Voltage Noise
IIN
VOUT/VIN
VOUT/IOUT
VOUT/TA
VOUT/t
ISC
VN
+2.7V VIN +5.5V
0mA ISOURCE 7mA
-7mA ISINK 0mA
TA = +125°C
TA = +25°C; first 1khrs
TA = +25°C
0.1Hz f 10Hz
350
900
nA
80
250
µV/V
25
100
µV/mA
50
150
µV/mA
100
ppm
50
ppm
50
mA
30
µVP-P
NOTES:
11. Compliance to datasheet limits is assured by one or more methods: production test, characterization, and/or design.
12. Across the specified temperature range. Temperature coefficient is measured by the box method where the change in VOUT is divided by the
temperature range: (-40°C to +85°C = +125°C, or -40°C to +105°C = +145°C for the ISL60002-33).
13. Thermal hysteresis is the change in VOUT measured at TA = +25°C after temperature cycling over a specified range, TA, VOUT is read initially at
TA = +25°C for the device under test. The device is temperature cycled and a second VOUT measurement is taken at +25°C. The difference between
the initial VOUT reading and the second VOUT reading is then expressed in ppm. For TA = +125°C, the device under test is cycled from +25°C to
+85°C to -40°C to +25°C, and for TA = +145°C, the device under test is cycled from +25°C to +105°C to -40°C to +25°C.
14. Long term drift is logarithmic in nature and diminishes over time. Drift after the first 1000 hours will be approximately 10ppm.
15. Short-circuit current (to VCC) for ISL60002-25 at VIN = 5.0V and +25°C is typically around 30mA. Shorting VOUT to VCC is not recommended due to
risk of resetting the part.
FN8082 Rev 22.00
Mar 9, 2018
Page 9 of 40