DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ST72324J2-AUTO データシートの表示(PDF) - STMicroelectronics

部品番号
コンポーネント説明
メーカー
ST72324J2-AUTO Datasheet PDF : 194 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
Flash program memory
ST72324xx-Auto
4.5
ICP (in-circuit programming)
To perform ICP the microcontroller must be switched to ICC (in-circuit communication) mode
by an external controller or programming tool.
Depending on the ICP code downloaded in RAM, Flash memory programming can be fully
customized (number of bytes to program, program locations, or selection serial
communication interface for downloading).
When using an STMicroelectronics or third-party programming tool that supports ICP and
the specific microcontroller device, the user needs only to implement the ICP hardware
interface on the application board (see Figure 6). For more details on the pin locations, refer
to the device pinout description.
t(s) 4.6
IAP (in-application programming)
c This mode uses a BootLoader program previously stored in Sector 0 by the user (in ICP
u mode or by plugging the device in a programming tool).
rod This mode is fully controlled by user software. This allows it to be adapted to the user
application, (such as user-defined strategy for entering programming mode, choice of
P communications protocol used to fetch the data to be stored). For example, it is possible to
te download code from the SPI or SCI interface and program it in the Flash. IAP mode can be
le used to program any of the Flash sectors except Sector 0, which is write/erase protected to
o allow recovery in case errors occur during the programming operation.
- Obs 4.7
Obsolete Product(s) 4.7.1
Related documentation
For details on Flash programming and ICC protocol, refer to the ST7 Flash Programming
Reference Manual and to the ST7 ICC Protocol Reference Manual.
Flash Control/Status Register (FCSR)
This register is reserved for use by programming tool software. It controls the Flash
programming and erasing operations.
FCSR
Reset value:0000 0000 (00h)
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Table 5. Flash control/status register address and reset value
Address (Hex.) Register label
7
6
5
4
3
2
1
0
0029h
FCSR reset value
0
0
0
0
0
0
0
0
26/193
Doc ID 13841 Rev 1