DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ECG001F-G データシートの表示(PDF) - TriQuint Semiconductor

部品番号
コンポーネント説明
メーカー
ECG001F-G
TriQuint
TriQuint Semiconductor TriQuint
ECG001F-G Datasheet PDF : 6 Pages
1 2 3 4 5 6
Absolute Maximum Ratings
Parameter
Rating
Storage Temperature
55 to 150 °C
RF Input Power, CW, 50Ω, T=25 °C +12dBm
Device Current (ICC)
150 mA
Operation of this device outside the parameter ranges
given above may cause permanent damage.
ECG001F-G
InGaP HBT Gain Block
Recommended Operating Conditions
Parameter
Min Typ Max Units
TCASE
−40
Tj for >106 hours MTTF
+85 °C
+160 °C
Electrical specifications are measured at specified test
conditions. Specifications are not guaranteed over all
recommended operating conditions.
Electrical Specifications
Test conditions unless otherwise noted: VSUPPLY = +5V, TCASE = +25 °C, RBIAS = 51 Ω, 50 Ω system
Parameter
Conditions
Min
Typ
Operational Frequency Range
DC
Gain
Output P1dB
Output IP3 (1)
Freq.=1000 MHz
OIP3 Pout= −1 dBm / tone, Δf= 1 MHz
22.2
+12.5
+25
Gain
19.2
20.7
Input Return Loss
35
Output Return Loss
Freq.=2000 MHz
18
Output P1dB
+12.5
Noise Figure
3.4
Device Voltage
+3.0
+3.4
Device Current  
30
Thermal Resistance, RTH
270 
Max
6000
21.8
+3.8
Units
MHz
dB
dBm
dBm
dB
dB
dB
dBm
dB
V
mA
°C / W
Typical RF Performance (1)
Test conditions unless otherwise noted: VSUPPLY = +5 V, Icc = 30 mA (typ.), RBIAS=51 Ω, Temp. =+25 °C, 50 Ω System
Parameter
Typical
Units
Frequency
100
500
900
1900 2140 2400 3500 5800
MHz
Gain
22.8
22.6
22.4
20.9
20.6
20.2
18.6
15.5
dB
Input Return Loss
48
46
42
35
29
28
22
14
dB
Output Return Loss
34
29
24
18
17
16
13
8
dB
Output P1dB
+11.6 +11.6 +12.6 +12.6 +12.6 +12.8 +12.2
+11
dBm
Output IP3 (2)
+23.6 +23.5 +24.8
+26
+25.6 +25.4
+23
dBm
Noise Figure
3.4
3.4
3.4
3.4
3.4
3.4
dB
Notes:
1. Gain and return loss values presented above, and in the plots of the following section, are measured at the device level.
Application specific performance values will differ in accordance with external components selected for the desired frequency
band of operation. P1dB, OIP3 and NF data is measured using the application circuit shown on page 4.
2. Pout= 1 dBm/tone, 1MHz tone spacing.
Datasheet: Rev. A 12-05-14
© 2014 TriQuint
- 2 of 6 -
Disclaimer: Subject to change without notice
www.triquint.com