DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CXA3268AR データシートの表示(PDF) - Sony Semiconductor

部品番号
コンポーネント説明
メーカー
CXA3268AR Datasheet PDF : 42 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CXA3268AR
Item
Symbol
Serial data
setting (HEX)
Measurement conditions
Min. Typ. Max. Unit
White limiter
variable amount
VWL1
VWL2
WHITE-LIM
00h
Set CONT = FFh, input SG2 (0.35Vp-p) to
TP71, measure the inverted and non-inverted ±1.2 ±0.6
±0
white limit level when WHITE-LIM = 00h and
03h, and assume the difference from the
V
WHITE-LIM output DC voltage as VWL1 and VWL2,
±0.6 ±1.2 ±1.8
03h respectively.
Black level
difference between VB
R, G and B
Measure the non-inverted black level at
TP32, TP34 and TP36, and obtain the
maximum and minimum difference between
these values.
300 mV
RGB and PSIG
output DC voltage
Vc
DC voltage
difference between Vc
RGB and PSIG
PSIG-BRT
variable amount
VPB1
VPB2
Measure the output DC level (average
voltage) at TP32, TP34, TP36 and TP39.
5.8 6.0 6.2 V
Measure the output average voltage
difference at TP32, TP34 and TP39 relative
to the output average voltage at TP36.
±200 mV
PSIG-BRT Measure the inverted and non-inverted black
01h level when PSIG-BRT = 01h and 7Fh and
PSIG-BRT
7Fh
assume the difference from the average DC
voltage Vc as VPB1 and VPB2, respectively.
±4.2
±0.7
V
USER-BRT
variable amount
UB1
UB2
Level difference
between PSIG-BLK VBB
and BLK-LIM
θ1
Hue
variable amount
θ2
U-BRT
00h
U-BRT
7Ah
Measure the inverted and non-inverted black
±0.8 ±1.5
level at TP36 when U-BRT = 00h and 7Ah
and assume the difference from the average
V
voltage as UB1 and UB2, respectively. ±4.5 ±4.9
SLWD
1
Set BLK-LIM = 00h and measure the
difference between the inverted and non-
inverted black level at TP36 and TP39.
350 mV
Set U-BRT = 23h, CONT = 80h, COLOR =
40h, and assume the amplitude at TP32
HUE 00h when SG4 (56mVp-p) is input to TP72 as V1. –20 –25
deg
Similarly, assume the amplitude at TP34
when SG4 (100mVp-p) is input to TP70 as V2.
θ = tan – 1 (V1/V2). Assume the θ when HUE
HUE FFh = 00h, 80h and FFh as θa, θb and θc,
respectively.
20 25
deg
θ1 = θa – θb, θ2 = θc – θb
Picture
variable amount
GP1
GP2
PIC-G
01h
PIC-G
1Fh
Set CONT = 2Fh, input SG3 to TP71, and
measure the TP36 amplitude at f0 relative to –1.5 0 1.5
the TP36 amplitude at 100kHz when PIC-G
dB
= 01h and 1Fh. f0 at PIC-f0 = 00h, 01h, 02h
and 03h is 2MHz, 2.2MHz, 2.6MHz and
10 12
2.9MHz, respectively.
Color
variable amount
GC1
GC2
COLOR
00h
COLOR
FFh
Input SG4 (50mVp-p) to TP70 and TP72,
and assume the output amplitude at TP32
–30 –20
and TP34 when COLOR = 00h, 80h and FFh
dB
as V1, V2 and V3, respectively.
GC1 = 20 log (V1/V2)
5.0 6.0
GC2 = 20 log (V3/V2)
– 15 –

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]