CGY 62
Electrical Characteristics
TA = 25 °C, VD = 4.5 V, RS = RL = 50 Ω, unless otherwise specified.
Characteristics
Symbol
Limit Values
min. typ. max.
Drain current
Power Gain
f = 200 MHz to 1800 MHz
f = 2500 MHz
ID
–
130
175
G
18
19
–
–
15
–
Gain flatness
f = 200 MHz to 1800 MHz
∆G
–
2
3.5
Noise figure
f = 200 MHz to 1800 MHz
F
–
3.5
4.0
Input return loss
f = 200 MHz to 500 MHz
f = 500 MHz to 2500 MHz
RLin
–
8
–
10
15
–
Output return loss
f = 200 MHz to 2500 MHz
RLout
10
13
–
Third order intercept point
two-tone intermodulation test
f1 = 806 MHz, f2 = 810 MHz
Po = – 10 dBm (both carriers)
Output power at 1 dB gain
compression
f = 200 MHz to 1800 MHz
IP3
–
30
–
P– 1 dB
–
17.5 –
Unit
mA
dB
dB
dB
dB
dB
dBm
dBm
Data Book
2
03.00